Ken Mattingly (CAPCOM)

Okay. We got caught in a station handover there. I didn't copy anything after you said you were putting it to DELTA-V test.

Frank Borman (CDR)

I ran—I ran three tests during that handover. Two over minus 19.6—two of them are minus 19.8; and one of them, minus 19.6.

Ken Mattingly (CAPCOM)

Okay. That sounds real fine.

Ken Mattingly (CAPCOM)

Okay. The other thing that—sometime prior to entry—and we're going to be looking at it—is the normal entry test pattern, and it's called out presently in the checklist as something we do around an hour. And we'd like to check if you can read the number on the scroll that is up now so we can see where we are in the test test pattern sequence. We're considering taking a look at one of these test patterns before we get into an hour so we can have more time to think about it in the event that there should be something anomalous in it.

Frank Borman (CDR)

Why don't we do it right now? We're on number 8.

Ken Mattingly (CAPCOM)

Okay. Understand; that's number 8, right?

Frank Borman (CDR)

Roger. It takes an awful long time to run them over there anyway. It won't hurt to do one.

Expand selection up Contract selection down Close
Ken Mattingly (CAPCOM)

Okay. If you'll stand by just a second; we're checking to see where we stand in the sequence of events for on pattern 8.

Frank Borman (CDR)

Another little thing about this EMS: you know, we had it set up when we separated from the booster —

Frank Borman (CDR)

— and the shock of the separation—the shock of the pyro's blowing in separation knocked it up to 100 and something.

Ken Mattingly (CAPCOM)

Understand. Knocked it up to 100.

Frank Borman (CDR)

Roger.

Expand selection down Contract selection up

Spoken on Dec. 26, 1968, 7:21 a.m. UTC (55 years, 10 months ago). Link to this transcript range is: Tweet

Ken Mattingly (CAPCOM)

Was the pyro separation enough that the—you felt a sensable g in the bird?

Frank Borman (CDR)

Roger. Let's just say there wasn't any question we were separating.

Frank Borman (CDR)

While you are checking the scroll, find out which entry pattern I should be using this bird in.

Ken Mattingly (CAPCOM)

Okay. While we are verifying that scroll position—they are talking it over in the back room about that now—I would like to go ahead and run down the checklist with you for entry.

Ken Mattingly (CAPCOM)

Okay. Looking on entry 1: the second item there is the 12-hour Kelvin cold soak, and in discussions I here and preflight, I think it is agreed that we don't want to do the cold soak there. So we are going to delete that step 2. And what it amounts to is, I think we do want to do a cold soak, and we certainly want to exercise the water boilers prior to entry in order to insure that we don't have one that is dried out, in the same manner that we had one dried out prior to LOI. And we are working on some procedures for that, and we'll have to come back to you with those a little bit later, and we will try to do it sometime when Bill's on the line so that everybody can get in on the loop at the same time. We would like to add a step between 8 and 9, or as part of step 8. This is all on page E-1, where we turn the VHF to Simplex A at minus 4 hours and 35 minutes. Now this will be beyond two-way VHF range, but it will make sure that we do have it on at the time when we pick it up. We were able to get out to 20 000 miles with a downlink, and we are checking on the uplink signal. So if we put it on at this point, we know we have it on well in advance of any time we might be able to get into the VHF.

Ken Mattingly (CAPCOM)

Okay. I guess maybe I have that backwards. They copy—you folks copied the VHF out to 20 KM. We're checking on the—on the downlink into that now. But in any event, this 4 hours and 35 minutes will get it well in advance of that.

Ken Mattingly (CAPCOM)

Okay, 8. We just got an answer back on the test patterns. We thought it was—We had 25 test patterns which are allocated to ground test, and these are the ones we've been looking at. Then there are five more that are allocated to flight, and the only difference in these patterns is that the flight patterns have instructions actually written on them; so if we are looking at test pattern 8, that means that we're still working on the ones that were allocated to the ground test, so there was no problem there. And I'll get you a number for which pattern we should be using for entry; working on that one right now. So we would like to go ahead and run through these.

Frank Borman (CDR)

I don't mean the test pattern. I say, I don't mean the test pattern. We asked them to put the supercircular on the number, the first place on the scroll; I'm sure they did. I'm sure it's the first pattern, but I just wanted to make sure that's right.

Ken Mattingly (CAPCOM)

Roger. That's why we are trying to verify. So —

Frank Borman (CDR)

You want me to run through a test pattern?

Ken Mattingly (CAPCOM)

Yes, sir. If you would, please. And if you'd tell us each step as you go through it.

Frank Borman (CDR)

Okay. Going through step 1; EMS test 1: wait 5 seconds. There's 5 seconds. Going AUTO. Okay- Indicator lights are all OFF; the range is zero, zero. Now I'm gonna slew the hairline over the notch. Okay. And now we go in EMS test 2.

Frank Borman (CDR)

Got the 0.05g light; all others are out.

Frank Borman (CDR)

Go on test 3: far side lower light on 10 seconds; going to set the range counter to 58. Okay. Set at 58; going to test 4.

Frank Borman (CDR)

Beautiful. It's perfect. It's right in the corridor. It comes down and stops at zero, zero.

Frank Borman (CDR)

Go in test 5: perfect again. Okay. Now I go to range set.

Frank Borman (CDR)

Okay. That was perfect.